WALLTITE® injection insulation

Used to reduce the heat loss of existing and new build cavity walls. Installed as a liquid through a pattern of 12mm pre-drilled holes it expands within the cavity to gently fill each void eventually setting as a rigid polyurethane high-density insulation.

 

Features and benefits

  • Low thermal conductivity 
  • Adds structural strength prolonging the life of the building
  • Seamless airtight insulation system with no joints or gaps 
  • Applied throughout Ireland by BASF Foam Masters 
  • Fast & easy applied with no waste, minimum fuss and maximum effect 
  • No VOC’s, CFC’s, formaldehyde and has no harmful side effects
  • Will not settle of sag and will last lifetime of building
  • BASF polyurethane is certified to BS EN ISO 9001, ISO/TS 16949:2002 & BS EN ISO 14001.
  • BBA & NSAI independently certified
  • Class 1 fire rating.

Technical downloads

Certification

WALLTITE® wall solutions

Cavity wall insulation
Walltite Cavity Wall InsulationWALLTITE cavity wall foam insulation is used to reduce the heat loss of existing and new build cavity walls consisting of masonry innerand outer leaf construction. Installed as a liquid through a pattern of 12mm pre-drilled holes it expands within the cavity to gently fill each void eventually setting as a rigid polyurethane high-density insulation. WALLTITE seals the cavity thereby preventing air leakage. The increased airtightness effect adds to the systems already superior thermal performance helping to reduce energy bills and creating a more comfortable living environment. WALLTITE insulation is also used to restore the structural stability of existing cavity walls in which conventional wall ties have corroded and in new build and reform construction where its resistance to flood water is of importance. WALLTITE stabilises the wall by adhering to the inner surfaces of the cavity and providing a continuous structural connection between the two leaves. It has excellent resistance to driving rain and can be installed in all geographical exposure zones.

Certification

BBA Certificate No. 13/5002. WALLTITE® has undergone various performance tests. Certificates are available on request.

Technical data

SpecificationFull fill, closed cell, cavity wall insulation and stabilisation system
NBS clauseF30, 10 and 150 P11, 50, 220, 230 and 24
Lambda 90/900.026 W/mK
Closed cell content94.4%
Adhesion to brick231k

Typical U-values

Thickness of WALLTITE (mm)U-value (W/m2K)
1500.18
1300.21
1000.24

Preparation

 

Application

 
Timber frame insulation
WALLTITE foam insulation is spray applied directly between timber studwork onto the OSB at the required thickness. Ordinarily a 25mm cavity will remain between the insulation and vapour control layers to allow for services. WALLTITE guarantees additional support and stability for the whole of the timber frame construction. The resulting continuous insulation and air barrier system will provide a cleaner, healthier more comfortable environment. WALLTITE Polyurethane spray is hypo allergenic and so contains no fibres or dust and no noxious vapours. BASF WALLTITE is very quickly installed by Foam Master contractors sing specialist  equipment.    

Certification

BBA Certificate No. 11/4816. WALLTITE® has undergone various performance tests. Certificates are available on request.

Typical detail

WALLTITE new timber frame detail
  1. Plasterboard and skim
  2. Vapour control layer to be lapped over DPC at floor level and returned to window reveal and jambs
  3. Unventilated air space
  4. Sheathing ply
  5. Breather membrane
  6. WALLTITE® CL100 insulation to achieve target U-value
  7. 50mm air gap
  8. Noggin to support plasterboard
  9. Sill plate
  10. DPC
  11. Treated timber cill support fixed to timber frame, clad and protected in DPC with insulation set above
Allow for differential movement at ALL openings, i.e. at window cill and window heads, as recommended by the timber frame manufacturer/UKTFA/TRADA: to accommodate differential movement and provide weather resistant and durable joint.

Techincal data

SpecificationInsulation sprayed between studwork
NBS clauseP10 205A
Lambda 90/900.025 to 0.028W/mK
Fire ratingClass 1 to BS 476 Part 7
Adhesion to timber136kPa

U-values

Thickness of WALLTITE (mm)U-value (W/m2K)
1350.20
1000.25
900.27
Masonry wall insulation – steel stud
WALLTITE spray foam insulation can be applied directly onto a solid dry masonry wall, between steel studwork fixed floor to ceiling. This allows for a layer of WALLTITE to remain unbridged by studwork thereby helping to reduce u-values further. The foam will engage any light steel framework to provide a more solid, secure wall when compared to other insulation methods. Ordinarily a 25mm cavity will remain between the insulation and vapour control layers to allow for services. WALLTITE guarantees additional support and stability for the whole of the wall construction. The resulting continuous insulation and air barrier system will provide a cleaner, healthier more comfortable environment for any “hard to treat” home situation.  

Certification

BBA Certificate No. 11/4816. WALLTITE® has undergone various performance tests. Certificates are available on request.

Typical detail

  1. WALLTITE® CL100 insulation between and behind studwork to achieve target U-value
  2. Galvanised metal frame independent of the wall
  3. Unventilated air space
  4. 12.5mm vapour check wallboard and skim finish

Techincal data

SpecificationDry lining of solid masonry wall
NBS clauseP10
Lambda 90/900.025 to 0.028W/mK
Fire ratingClass 1 to BS 476 Part 7
µ61.12

U-values

Thickness of WALLTITE (mm)U-value (W/m2K)
1200.20
850.26
650.34
Masonry wall insulation – timber stud
WALLTITE spray foam insulation can be applied directly onto a solid dry masonry wall, between timber studwork either fixed directly to the wall or anchored floor to ceiling. The latter method allows for a layer of WALLTITE to remain unbridged by timber thereby helping to reduce u-values even further. Ordinarily a 25mm cavity will remain between the insulation and vapour control layers to allow for services. WALLTITE guarantees additional support and stability for the whole of the timber frame construction. The resulting continuous insulation and air barrier system will provide a cleaner, healthier more comfortable environment for any “hard to treat” home situation.  

Certification

BBA Certificate No. 11/4816. WALLTITE® has undergone various performance tests. Certificates are available on request.

Typical detail

Masonry wall insulation – Timber Stud
  1. 25mm WALLTITE® behind studwork
  2. Treated timber studs set off by wall by brackets
  3. WALLTITE® CL100 insulation between and behind studwork to achieve target U-value
  4. Unventilated air space
  5. 12.5mm vapour check wallboard and skim finish
At corners of internal and external walls to rooms, set frame to external wall back from corner a minimum of 25mm and set batten to line with vapour check wall boarding to receive board end to internal wall.

Techincal data

SpecificationDry lining of solid masonry wall
NBS clauseP10 15A
Lambda 90/900.025 to 0.028W/mK
Fire ratingClass 1 to BS 476 Part 7
µ61.12

U-values

Thickness of WALLTITE (mm)U-value (W/m2K)
1200.20
850.26
650.34